41 research outputs found

    Superficial characteristics of titanium after treatment of chorreated surface, passive acid, and decontamination with argon plasma

    Get PDF
    Background. Titanium is characterized by its biocompatibility, resistance to maximum stress, and fatigue and non-toxicity. The composition, surface structure, and roughness of titanium have a key and direct influence on the osseointegration processes when it is used in the form of dental implants. The objective of the present study is to characterize, at chemical, superficial, and biological levels, the result of the application of the sandblasted with large-grit and acid-etched (SLA) treatment consisting of coarse-grained and double-passivated acid blasting with subsequent decontamination with argon plasma on the surface of titanium implants type IV. (2) Methods. Four Oxtein® dental implants (Zaragoza, Spain) were investigated with the following coding: Code L63713T (titanium grade IV, 3.75 mm in diameter, and 13 mm in length). The surface of the implants was SLA type obtained from coarse-grained, double passivated acid, and decontaminated with argon plasma. The samples were in their sealed packages and were opened in our laboratory. The X-ray photoelectron spectroscopy (XPS) technique was used to characterize the chemical composition of the surface, and the scanning electronic microscope (SEM) technique was used to perform topographic surface evaluation. Cell cultures were also performed on both surfaces. (3) Results. The superficial chemical analysis of the studied samples presented the following components, approximately, expressed in atomic percentage: O: 39%; Ti: 18%; C: 39%; N: 2%; and Si: 1%. In the same way, the topographic analysis values were obtained in the evaluated roughness parameters: Ra: 1.5 μm ± 0.02%; Rq: 1.31 μm ± 0.33; Rz: 8.98 μm ± 0.73; Rp: 5.12 μm ± 0.48; Rv: 3.76 μm ± 0.51; and Rc: 4.92 μm ± 0.24. At a biological level, the expression of osteocalcin was higher (p < 0.05) on the micro-rough surface compared to that machined at 48 and 96 h of culture. (4) Conclusions. The data obtained in our study indicate that the total carbon content, the relative concentration of titanium, and the roughness of the treatment performed on the implants are in agreement with those found in the literature. Further, the roughness of the treatment performed on the implants throws a spongy, three-dimensional surface suitable for bone growth on it. The biological results found are compatible with the clinical use of the surface tested

    Superficial characteristics of titanium after treatment of chorreated surface, passive acid, and decontamination with argon plasma

    Get PDF
    Background. Titanium is characterized by its biocompatibility, resistance to maximum stress, and fatigue and non-toxicity. The composition, surface structure, and roughness of titanium have a key and direct influence on the osseointegration processes when it is used in the form of dental implants. The objective of the present study is to characterize, at chemical, superficial, and biological levels, the result of the application of the sandblasted with large-grit and acid-etched (SLA) treatment consisting of coarse-grained and double-passivated acid blasting with subsequent decontamination with argon plasma on the surface of titanium implants type IV. (2) Methods. Four Oxtein® dental implants (Zaragoza, Spain) were investigated with the following coding: Code L63713T (titanium grade IV, 3.75 mm in diameter, and 13 mm in length). The surface of the implants was SLA type obtained from coarse-grained, double passivated acid, and decontaminated with argon plasma. The samples were in their sealed packages and were opened in our laboratory. The X-ray photoelectron spectroscopy (XPS) technique was used to characterize the chemical composition of the surface, and the scanning electronic microscope (SEM) technique was used to perform topographic surface evaluation. Cell cultures were also performed on both surfaces. (3) Results. The superficial chemical analysis of the studied samples presented the following components, approximately, expressed in atomic percentage: O: 39%; Ti: 18%; C: 39%; N: 2%; and Si: 1%. In the same way, the topographic analysis values were obtained in the evaluated roughness parameters: Ra: 1.5 μm ± 0.02%; Rq: 1.31 μm ± 0.33; Rz: 8.98 μm ± 0.73; Rp: 5.12 μm ± 0.48; Rv: 3.76 μm ± 0.51; and Rc: 4.92 μm ± 0.24. At a biological level, the expression of osteocalcin was higher (p < 0.05) on the micro-rough surface compared to that machined at 48 and 96 h of culture. (4) Conclusions. The data obtained in our study indicate that the total carbon content, the relative concentration of titanium, and the roughness of the treatment performed on the implants are in agreement with those found in the literature. Further, the roughness of the treatment performed on the implants throws a spongy, three-dimensional surface suitable for bone growth on it. The biological results found are compatible with the clinical use of the surface tested

    In vitro comparative study of fibroblastic behaviour on polymethacrylate (PMMA) and lithium disilicate polymer surfaces

    Get PDF
    Polymethyl methacrylate (PMMA) and lithium disilicate are widely used materials in the dental field. PMMA is mainly used for the manufacture of removable prostheses; however, with the incorporation of CAD-CAM technology, new applications have been introduced for this material, including as a provisional implant attachment. Lithium disilicate is considered the gold standard for definitive attachment material. On the other hand, PMMA has begun to be used in clinics as a provisional attachment until the placement of a definitive one occurs. Although there are clinical studies regarding its use, there are few studies on cell reorganization around this type of material. This is why we carried out an in vitro comparative study using discs of both materials in which human gingival fibroblasts (HGFs) were cultured. After processing them, we analyzed various cellular parameters (cell count, cytoskeleton length, core size and coverage area). We analyzed the surface of the discs together with their composition. The results obtained were mostly not statistically significant, which shows that the qualities of PMMA make it a suitable material as an implant attachment

    Influence of Titanium Oxide Pillar Array Nanometric Structures and Ultraviolet Irradiation on the Properties of the Surface of Dental Implants: A Pilot Study

    Get PDF
    Aim: Titanium implants are commonly used as replacement therapy for lost teeth and much current research is focusing on the improvement of the chemical and physical properties of their surfaces in order to improve the osseointegration process. TiO2, when it is deposited in the form of pillar array nanometric structures, has photocatalytic properties and wet surface control, which, together with UV irradiation, provide it with superhydrophilic surfaces, which may be of interest for improving cell adhesion on the peri-implant surface. In this article, we address the influence of this type of surface treatment on type IV and type V titanium discs on their surface energy and cell growth on them. Materials and methods: Samples from titanium rods used for making dental implants were used. There were two types of samples: grade IV and grade V. In turn, within each grade, two types of samples were differentiated: untreated and treated with sand blasting and subjected to double acid etching. Synthesis of the film consisting of titanium oxide pillar array structures was carried out using plasma-enhanced chemical vapor deposition equipment. The plasma was generated in a quartz vessel by an external SLAN-1 microwave source with a frequency of 2.45 GHz. Five specimens from each group were used (40 discs in total). On the surfaces to be studied, the following determinations were carried out: (a) X-ray photoelectron spectroscopy, (b) scanning electron microscopy, (c) energy dispersive X-ray spectroscopy, (d) profilometry, (e) contact angle measurement or surface wettability, (f) progression of contact angle on applying ultraviolet irradiation, and (g) a biocompatibility test and cytotoxicity with cell cultures. Results: The application of ultraviolet light decreased the hydrophobicity of all the surfaces studied, although it did so to a greater extent on the surfaces with the studied modification applied, this being more evident in samples manufactured in grade V titanium. In samples made in grade IV titanium, this difference was less evident, and even in the sample manufactured with grade IV and SLA treatment, the application of the nanometric modification of the surface made the surface optically less active. Regarding cell growth, all the surfaces studied, grouped in relation to the presence or not of the nanometric treatment, showed similar growth. Conclusions. Treatment of titanium oxide surfaces with ultraviolet irradiation made them change temporarily into superhydrophilic ones, which confirms that their biocompatibility could be improved in this way, or at least be maintained

    Comparison of cytomorphometry and early cell response of human gingival fibroblast (HGFs) between zirconium and new zirconia-reinforced lithium silicate ceramics

    Get PDF
    New zirconia-reinforced lithium silicate ceramics (ZLS) could be a viable alternative to zirconium (Y-TZP) in the manufacture of implantological abutments—especially in aesthetic cases—due to its good mechanical, optical, and biocompatibility properties. Although there are several studies on the ZLS mechanical properties, there are no studies regarding proliferation, spreading, or cytomorphometry. We designed the present study which compares the surface, cellular proliferation, and cellular morphology between Y-TZP (Vita YZ® T [Vita Zahnfabrik (Postfach, Germany)]) and ZLS (Celtra® Duo [Degudent (Hanau-Wolfgang, Germany)]). The surface characterization was performed with energy dispersive spectroscopy (EDS), scanning electron microscopy (SEM), and optical profilometry. Human gingival fibroblasts (HGFs) were subsequently cultured on both materials and early cellular response and cell morphology were compared through nuclear and cytoskeletal measurement parameters using confocal microscopy. The results showed greater proliferation and spreading on the surface of Y-TZP. This could indicate that Y-TZP continues to be a gold standard in terms of transgingival implant material: Nevertheless, more in vitro and in vivo research is necessary to confirm the results obtained in this study

    Sialolitiasis parotídea del conducto de Stensen

    Get PDF
    Salivary duct lithiasis is a condition characterized by the obstruction of a salivary gland or its excretory duct due to the formation of calcareous concretions or sialoliths resulting in salivary ectasia and even provoking the subsequent dilation of the salivary gland. Sialolithiasis accounts for 30% of salivary diseases and most commonly involves the submaxillary gland (83 to 94%) and less frequently the parotid (4 to 10%) and sublingual glands (1 to 7%). The present study reports the case of a 45-year-old male patient complaining of bad breath and foul-tasting mouth at meal times and presenting with a salivary calculus in left Stensen´s duct. Once the patient was diagnosed, the sialolith was surgically removed using local anesthesia. In this paper we have also updated a series of concepts related to the etiology, diagnosis and treatment of sialolithiasis.La litiasis salival es una afectación consistente en la obstrucción mecánica de una glándula salival o de su conducto excretor, debido a la formación de concreciones calcáreas o sialolitos, lo que determina una ectasía salival, pudiendo provocar la dilatación posterior de la glándula. La sialolitiasis supone el 30 % de la patología salival y afecta principalmente a las glándulas submaxilares (83 a 94 %), seguida por la glándula parótida (4 a 10 %) y las glándulas sublinguales (1 a 7 %). En este trabajo presentamos el caso de un paciente varón de 45 años que presentaba mal olor y sabor de boca en el momento de las comidas y afecto de un cálculo salival a nivel del conducto de Stensen izquierdo. Tras el diagnóstico de la sintomatología, el sialolito se eliminó quirúrgicamente bajo anestesia local. De igual forma realizamos una actualización de conceptos en relación con la etiología, diagnóstico y tratamiento de esta patología

    Biocompatibility of Polymer and Ceramic CAD/CAM Materials with Human Gingival Fibroblasts (HGFs)

    Get PDF
    Four polymer and ceramic computer-aided design/computer-aided manufacturing (CAD/CAM) materials from different manufacturers (VITA CAD-Temp (polymethyl methacrylate, PMMA), Celtra Duo (zirconia-reinforced lithium silicate ceramic, ZLS), IPS e.max CAD (lithium disilicate (LS2)), and VITA YZ (yttrium-tetragonal zirconia polycrystal, Y-TZP)) were tested to evaluate the cytotoxic effects and collagen type I secretions on human gingival fibroblasts (HGFs). A total of 160 disc-shaped samples (Ø: 10 ± 2 mm; h: 2 mm) were milled from commercial blanks and blocks. Direct-contact cytotoxicity assays were evaluated at 24, 48, and 72 h, and collagen type I (COL1) secretions were analysed by cell-based ELISA at 24 and 72 h. Both experiments revealed statistically significant differences (p < 0.05). At 24 and 48 h of contact, cytotoxic potential was observed for all materials. Later, at 72 h, all groups reached biologically acceptable levels. LS2 showed the best results regarding cell viability and collagen secretion in all of the time evaluations, while Y-TZP and ZLS revealed intermediate results, and PMMA exhibited the lowest values in both experiments. At 72 h, all groups showed sharp decreases in COL1 secretion regarding the 24-h values. According to the results obtained and the limitations of the present in vitro study, it may be concluded that the ceramic materials revealed a better cell response than the polymers. Nevertheless, further studies are needed to consolidate these findings and thus extrapolate the results into clinical practic

    Dimensional Changes in the Alveolus after a Combination of Immediate Postextraction Implant and Connective Grafting and/or Socket Shield Techni

    Get PDF
    : Immediate implant placement protocols after dental extraction have enabled a reduction in surgical phases. This procedure has increased patient satisfaction and similar survival rates to late implant placement procedures. However, placing an implant immediately after dental extraction does not counteract the physiological remodeling of alveolar bone. For this reason, additional surgical techniques have been developed, such as the placement of a connective tissue graft (CTG) or the socket shield technique (SST). Dimensional changes in the peri-implant tissues were observed after placement of immediate implants following the extraction and CTG and/or SST. A total of 26 surgical interventions were carried out in which dimensional change variables of peri-implant tissues were analyzed. The preoperative state and immediate postoperative situation were compared with the situation after one year. Measurements were taken at 3, 5, and 7 mm from the gingival margin and analyzed in this CBCT radiological study (Planmeca Promax 3D). The implant platform was used as a reference point for the measurement of changes in alveolar crest height. One year after performing either of the two techniques (CTG and/or SST), a significant increase in the gingiva thickness and vestibular cortex occurred at 5 mm (0.65 ± 1.16 mm) and 7 mm (0.95 ± 1.45 mm) from the gingival margin. Additionally, an increase in thickness of palatal bone was registered at 3 mm (0.48 ± 0.90 mm). The graft placement group showed an increase in thickness of peri-implant tissue in the vestibular area after one year, although CTG and SST groups were clinically similar. The implementation of SST revealed promising results regarding the buccal thickness of hard and soft tissues after one year. A significant increase in vestibular cortical bone thickness, as well as the overall mucosa thickness and buccal bone at 3 mm from the gingival margin, was observed. A significant reduction in the distance from the bone crest to the platform was detected in both techniques. Both techniques (CTG and SST) are appropriate to provide sufficient volume to peri-implant tissues in the vestibular area of anterior maxillary implants. Some limitations were detected, such as the lack of an aesthetic analysis or small sample size, so results should be interpreted with caution. Future studies are necessary to further evaluate the long-term predictability of these techniques

    Conservative management of dentigerous cysts in children

    Get PDF
    Purpose and Introduction: Dentigerous cysts are epithelial in origin and are the most commonly found cyst in children. The majority of these lesions are usually a radiological finding and are capable of quite large before being diagnosed. The standard treatment for these cysts is the enucleation and the extraction of the affected tooth. However, if the patient is a child and the affected tooth is not developed, a more conservative attitude should be considered. Material and Methods: (Clinical case): A 7-year-old patient is presented with an eruptive backlog of the lower permanent first molars. Radiological examination reveals two radiolucid lesions in relation to them, which are compatible with a dentigerous cyst, and in relation to the inferior aveolar nerve and various germs. A partial enucleation is carried out, maintaining all the dental germs related to the cyst in mouth and monitoring the patient until the case study is over. Results and Discussion: Diagnosis and early treatment of these lesions in children is of great importance, especially in cases where the lesions enclose permanent teeth

    Parotid sialolithiasis in Stensen´s duct

    Get PDF
    La litiasis salival es una afectación consistente en la obstrucción mecánica de una glándula salival o de su conducto excretor, debido a la formación de concreciones calcáreas o sialolitos, lo que determina una ectasía salival, pudiendo provocar la dilatación posterior de la glándula. La sialolitiasis supone el 30 % de la patología salival y afecta principalmente a las glándulas submaxilares (83 a 94 %), seguida por la glándula parótida (4 a 10 %) y las glándulas sublinguales (1 a 7 %). En este trabajo presentamos el caso de un paciente varón de 45 años que presentaba mal olor y sabor de boca en el momento de las comidas y afecto de un cálculo salival a nivel del conducto de Stensen izquierdo. Tras el diagnóstico de la sintomatología, el sialolito se eliminó quirúrgicamente bajo anestesia local. De igual forma realizamos una actualización de conceptos en relación con la etiología, diagnóstico y tratamiento de esta patologíaSalivary duct lithiasis is a condition characterized by the obstruction of a salivary gland or its excretory duct due to the formation of calcareous concretions or sialoliths resulting in salivary ectasia and even provoking the subsequent dilation of the salivary gland. Sialolithiasis accounts for 30% of salivary diseases and most commonly involves the submaxillary gland (83 to 94%) and less frequently the parotid (4 to 10%) and sublingual glands (1 to 7%). The present study reports the case of a 45-year-old male patient complaining of bad breath and foul-tasting mouth at meal times and presenting with a salivary calculus in left Stensen´s duct. Once the patient was diagnosed, the sialolith was surgically removed using local anesthesia. In this paper we have also updated a series of concepts related to the etiology, diagnosis and treatment of sialolithiasis
    corecore